BOP, 18 3/4", 10000 psi - Cameron U2 Stack    QTY.: 1 stack

Unit / Lot:

04632

Area:

USA   Location: Houston, Texas, USA Map

Info:

CIW BOP 18 3/4" -10K, Type UII, hub connection, (1 each double ram), 1 each single ram, 1 each 5K annular "D" with 10K Hub btm connection and 5K studded top.

Price:

On Request

Status:

DETAILS

Year of manufacture:

1984

Manufacturer:

Cameron

Type:

Type UII and "D"

Manufacturers Part No.:


Documentation:

Available

Inspection Status:

Report by Cameron available


Main components included:

1 ea. Cameron 18 3/4" x 5,000 PSI WP type "D" annular BOP. Top connection: Studded top x BX163 ring groove. Bottom connection: #27 Clamp Hub x BX164 ring groove, SS Lined Ring grooves, H2S service. Part Number 235940-00-56-01, Serial Number FB-1299.

1 ea. Cameron 18 3/4" x 10,000 PSI WP Single type UII Ram BOP. Top/bottom connection: #27 Clamp Hub x BX164 ring groove, furnished with 2 ea. 4 1/16" #6 Clamp Hub side outlets x BX155 ring grooves, SS Lined Ring grooves, H2S service, Wedge lock assemblies. Part Number 235940-00-55-01, Serial Number: FB-1303.

SOLD: 1 ea. Cameron 18 3/4" x 10,000 PSI WP Double type UII Ram BOP. Top/bottom connection: #27 Clamp Hub x BX164 ring groove, furnished with 4 ea. 4 1/16" #6 Clamp Hub side outlets x BX155 ring grooves, SS Lined Ring grooves, H2S service, Wedge lock assemblies. Part Number 235940-00-55-23, Serial Number FB-1305.
Note: This double ram BOP has been sold sold, but we may offer an additional UII double ram BOP. Details available on request.


Misc. accessories:
1 set CIW # 27 Clamp assemblies (18 3/4" 10K).
6 set CIW # 6 Clamp assemblies. (4 1/16" 10K).
3 each Valve, Gate, Manual, Cameron McEvoy.
4 each Valve, Gate, Hydr., Cameron McEvoy.
(No Ram blocks included)

Status:
The BOP stack was previously used on the Heimdal fixed offshore wellhead platform in the North Sea, currently operated by Statoil.
The equipment has been dismantled for inspection and repair.
Inspection report from Cameron is available upon request.
Some minor parts are missing: tba.

Documentation:
1 Set of original traceability documentation included.
The BOP stack was originally certified by DNV for use offshore in Norway..


Note: The CIW type "U2" BOP has many parts that interchange with the type "U" BOP.

We can also supply 2 each 18 3/4" x 10,000 PSI High Pressure Risers, see UL 04633 --> Equipment Directory